LED Project 300W LED Display Module Driver/Power Supply 30mm with Triple Proof PCB
LPH300S5W8-A is a 300W without fan LED display power supply. The input voltage rang is 176~264VAC and output voltage is 5V. It can be applied to Led display, LED indicator light and other Led display fields. This product is ultra-thin design, with a height of only 30mm, and can adapt to a variety of box size requirements. Super high efficiency, compact shell design and good heat dissipation ensure the long-term stable work.
Place of Origin: CHINA Brand Name: Hangtepower Model Number: LPH300S5W8-A
Detailed introduction
Description
LPH300S5W8-A is a 300W without fan LED display power supply. The input voltage rang is 176~264VAC and output voltage is 5V. It can be applied to Led display, LED indicator light and other Led display fields. This product is ultra-thin design, with a height of only 30mm, and can adapt to a variety of box size requirements. Super high efficiency, compact shell design and good heat dissipation ensure the long-term stable work.
- Features:
- Standard slim case, 30mm height
- Input Volt: 176~264VAC
- Working temp: -40℃~ 70℃ (refer to derating curve)
- Fan-less, air-cooled
- Protection: Short circuit/Overload
- 100% aging test
- High efficiency & reliability
- 2 years warranty
- Function:
- Converting 220 Volt voltage to 5 Volt, powering for LED display, light etc
- Reference standard:
- GB4943/EN60950/GB2324/EN55022/GB/T17626 IEC61000-4, -6-1, -6-2, GB17625.1-1998/GB/T 14714
Specifications
Model | LPH300S5W8-A | |
Input | Input voltage | 176~264VAC |
Input current | 240VAC/4A | |
Efficiency | ≥88% | |
Frequency range | 47~63HZ | |
Leakage current | <1.5mA/230VAC | |
Inrush current | Cold start, 50A/230VAC | |
PF | 0.5 | |
Output | DC voltage | 5V |
Rated current | 60A | |
Rated power | 300W | |
Voltage ADJ. range | -- | |
Ripple & Noise | <200mVp-p | |
Setup, rise | 2500ms,50ms/230VAC at full load | |
hold up time | 5ms/230VAC at full load | |
Line regulation | ±0.5% | |
Load regulation | ±2.0% | |
Voltage tolerance | ±3.0% | |
EMC | Interrupt, fall | Compliance to: EN6100-4-11/C |
Vibration | 10~500Hz, 2G 10min. /1 cycle, 6 cycle each X, Y, Z axes | |
Shock | 20G/11mS pulse, 3 times at each X, Y, Z axes | |
Safety | Safety standard | Compliance to: GB4943/UL60950 |
Withstand voltage | I/P-O/P: 3.0KVac/10mA; I/P-CASE: 1.5KVac/10mA; O/P-CASE: 0.5KVAC/10mA 1min for | |
Isolation resistance | I/P-O/P: 100M ohms; I/P-Case: 100M ohms; O/P-Case: 100M ohms | |
Protection | Over voltage | / |
Over load | 110~150% rated Hiccup mode, auto-recovery | |
Over current | 72-92A error eliminated, auto-recovery | |
Short circuit | Hiccup mode, auto-recovery | |
Environment | Working Temp&humidity | -40~70℃ 20%~95%RH non-condensing (Refer to Derating Curve) |
Storage Temp&humidity | -40℃~85℃; 10%~95%RH non-condensing | |
Vibration | 10~500Hz, 2G,10min/1 cycle, 60min. each along X, Y, Z axes | |
Impact | 20G,last 11mS,3 impacts along X, y and Z axes | |
Altitude | the ambient temperature derating of 0.6 ℃/100m for operating altitude higher | |
Reliability | MTBF | Under 25℃: 100000Hrs, MIL-217 Method 2 |
Others | Size | 212*82*30 mm(L*W*H) |
Packing | 0.45Kg/pc, 30pcs/ctn,14.6KG/ctn | |
Cold mode | ☑free air convection □with fan | |
More options | □ PCB double side conformal coating □ Terminal with cover □ low temp start | |
*In order to extend the service life, it is recommended to leave 30% more allowance when loading. For example, if the equipment needs 100W power, please choose the power supply over 130W. *Ripple&noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. *All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature。 *the auxiliary heat dissipation of aluminum plate with an area of 300 * 300 * 5mm must be used when full load working. *The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. All our EMC tests are carried out by mounting samples on metal plates. |
Quick Detail
● Model Encoding:
● Derating curve :
● Static characteristic curve :
● Mechanical drawing:
●
Installation:
1、Use mounting screws by M3*6mm
2、Max depth of screws into housing is 4mm
● Use instructions:
1、Please follow the installation instructions when use the power supply.
2、Before power on test run after installation, please check and proofread the wiring on each terminal, make sure that the input and output, AC and DC, positive and negative, voltage and current values are correct, prevent the occurrence of wrong connection, and avoid damaging the power supply and user equipment.
3、Before power on, please use a multi meter to measure whether the live wire, zero wire and ground wire are short circuited, and whether the output terminal is short circuited; it is better to start without load when power on.
4、Do not exceed the nominal value of the power supply when using, so as not to affect the reliability of the product. If you need to change the output parameters of the power supply, please consult our technical department before using.
5、In order to ensure the safety of use and reduce interference, please ensure that the grounding terminal is reliably grounded(ground wire please thicker than AWG18#).
6、If the power supply fails, please do not repair it without permission. Please contact our customer service department as soon as possible, customer service line:
● Transportation & Storage instructions
1、Transport:
The package is suitable for shipping by automobiles, ships, airs, trains, etc. During transportation, it shall be rain proof, loaded and unloaded gently.
2、Storage:
When the product is not in use, it shall be placed in the packing box. The storage environment temperature and relative humidity shall meet the requirements of the product. No corrosive gas or product in the warehouse, and no strong mechanical vibration, impact and strong magnetic field. The packing box shall be padded at least 20cm above the ground, and not be soaked. If the storage time is too long (more than 1 year), it shall be rechecked by professionals before use.