All Categories

LED Display Power Supply

Home > PRODUCTS > LED Display Power Supply

Cooling 200W LED Display Module Driver/ Power Supply 5V/4.5/4.2V Optional with Triple Proof PCB

    • LV-200-5P is a 200W fan-less LED display power supply. The input voltage rang is 176~264VAC and output voltage is 5V. It can be applied to Led display, LED indicator light and other Led display fields. Super high efficiency, compact shell design and good heat dissipation ensure the long-term stable work
      Place of Origin:CHINA
      Brand Name:Hangtepower
      Model Number:LV-200-5P
INQUIRY DOWNLOAD

Detailed introduction

Description

LV-200-5P is a 200W fan-less LED display power supply. The input voltage rang is 176~264VAC and output voltage is 5V. It can be applied to Led display, LED indicator light and other Led display fields. Super high efficiency, compact shell design and good heat dissipation ensure the long-term stable work.

Features:
Standard case
Input Volt: 176~264VAC
Working temp: -40℃~ 70℃ (refer to derating curve)
Fan-less, air-cooled
Protection: Short circuit/Overload
100% aging test
High efficiency & reliability
2 years warranty
Function:
Converting 220 Volt voltage to 5 Volt, powering for LED display, light etc
Reference standard:
GB4943/EN60950/GB2324/EN55022/GB/T17626 IEC61000-4, -6-1, -6-2, GB17625.1-1998/GB/T 14714
Specifications
ModelLV-200- 5P
InputInput voltage176~264VAC
Input current240VAC/3A
Efficiency≥87%
Frequency range47~63HZ
Leakage current<1.5mA/230VAC
Inrush currentCold start, 50A/230VAC
PFC-
OutputDC voltage5V
Rated current40A
Rated power200W
Ripple & Noise<250mVp-p
Setup, rise2500ms,50ms/230VAC at full load
hold up time5ms/230VAC at full load
Line regulation±0.5%
Load regulation±2.0%
Voltage tolerance±3.0%
EMCInterrupt, fallCompliance to: EN6100-4-11/C
Vibration10~500Hz, 2G 10min. /1 cycle, 6 cycle each X, Y, Z axes
Shock20G/11mS pulse, 3 times at each X, Y, Z axes
SafetySafety standardCompliance to: GB4943/UL60950
Withstand voltageI/P-O/P: 3.0KVac/10mA; I/P-CASE: 1.5KVac/10mA; O/P-CASE: 0.5KVAC/10mA 1min for
Isolation resistanceI/P-O/P: 100M ohms; I/P-Case: 100M ohms; O/P-Case: 100M ohms
ProtectionOver voltage/
Over load110~150% rated  Hiccup mode, auto-recovery
Over current48-76A error eliminated, auto-recovery
Short circuitHiccup mode, auto-recovery
EnvironmentWorking Temp&humidity-40~70℃   20%~95%RH  non-condensing   (Refer to Derating Curve)
Storage Temp&humidity-40℃~85℃; 10%~95%RH  non-condensing
Vibration10~500Hz, 2G,10min/1 cycle, 60min. each along X, Y, Z axes
Impact20G,last 11mS,3 impacts along X, y and Z axes
Altitudethe ambient temperature derating of 0.6 ℃/100m for operating altitude higher
ReliabilityMTBFUnder 25℃: 100000Hrs, MIL-217 Method 2
OthersSize200*110*50 mm(L*W*H)
Packing0.47Kg/pc, 20pcs/ctn,10.5KG/ctn
Cold mode☑free air convection     □with fan
More options□ PCB double side conformal coating □ Terminal with cover □ low temp start
 
 
*In order to extend the service life, it is recommended to leave 30% more allowance when loading. For example, if the equipment needs 100W power, please choose the power supply over 130W.
*Ripple&noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
*All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
*the auxiliary heat dissipation of aluminum plate with an area of 300 * 300 * 5mm must be used when full load working.
*The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. All our EMC tests are carried out by mounting samples on metal plates.
Quick Detail

● Derating curve :

● Static characteristic curve :

● Mechanical drawing:

undefined


Installation:

1、Use mounting screws by M3*6mm

2、Max depth of screws into housing is 3mm

● Use instructions:

1、Please follow the installation instructions when use the power supply.

2、Before power on test run after installation, please check and proofread the wiring on each terminal, make sure that the input and output, AC and DC, positive and negative, voltage and current values are correct, prevent the occurrence of wrong connection, and avoid damaging the power supply and user equipment.

3、Before power on, please use a multi meter to measure whether the live wire, zero wire and ground wire are short circuited, and whether the output terminal is short circuited; it is better to start without load when power on.

4、Do not exceed the nominal value of the power supply when using, so as not to affect the reliability of the product. If you need to change the output parameters of the power supply, please consult our technical department before using.

5、In order to ensure the safety of use and reduce interference, please ensure that the grounding terminal is reliably grounded(ground wire please thicker than AWG18#).

6、If the power supply fails, please do not repair it without permission. Please contact our customer service department as soon as possible, customer service line:

● Transportation & Storage instructions

1、Transport:

The package is suitable for shipping by automobiles, ships, airs, trains, etc. During transportation, it shall be rain proof, loaded and unloaded gently.

2、Storage:

When the product is not in use, it shall be placed in the packing box. The storage environment temperature and relative humidity shall meet the requirements of the product. No corrosive gas or product in the warehouse, and no strong mechanical vibration, impact and strong magnetic field. The packing box shall be padded at least 20cm above the ground, and not be soaked. If the storage time is too long (more than 1 year), it shall be rechecked by professionals before use.

INQUIRY