• 30mm ultra-thin power supply, wide range of applications
  • Wide input voltage range, strong adaptability
  • -30℃~+70℃ wide working temp.
  • According to US standard: UL60950
  • Using top brand components
  • Overvoltage, overcurrent, and overload protection
  • 100% full-load aging at high temperature , low failure rate and high reliability

SPECIFICATION (Measured at 230Vac, 25℃. Unless otherwise noted)

ItemSpecifications
Output Voltage Selectable12V;24V
Overload protectionAutomatically resume work after the overload fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Output short circuit protectionAutomatically resume work after the output short-circuit fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Over voltage protectionPrevent from being damaged or burnt due to excessive voltage
Withstand voltageIP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc
Working temperature-40~70℃
Start-up Time<3Sec
Safety standardsGB4943/EN60950
EMCstandardsIEC61000-4
Connection9.5mm screw terminial
Dimension(L*W*H)99±1mm×82±1mm×30±1mm

Product

ModelInputOutputCurrentR&NEffiTempStorage temperature
PRA-50-12AC176-264V12V4.2A<300mV83%-40-70℃-40℃-85℃
PRA-50-24AC176-264V24V2.1A<300mV85%-40-70℃-40℃-85℃
  • Using self-developed patented circuit design, high efficiency, low heat generation
  • Wide input voltage range, strong adaptability
  • -40℃~+70℃ wide working temperature
  • According to US standard: UL60950
  • Using top brand components, better quality
  • 100% full-load aging at high temperature , low failure rate and high reliability
  • Overvoltage, overcurrent, and overload protection

SPECIFICATION (Measured at 230Vac, 25℃. Unless otherwise noted)

ItemSpecifications
Output Voltage Selectable12V;24V
Overload protectionAutomatically resume work after the overload fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Output short circuit protectionAutomatically resume work after the output short-circuit fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Over voltage protectionPrevent from being damaged or burnt due to excessive voltage
Withstand voltageIP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc
Working temperature-40~70℃
Start-up Time<3Sec
Safety standardsGB4943/EN60950
EMCstandardsIEC61000-4
Connection9.5mm screw terminial
Dimension(L*W*H)208±1mm×59±1mm×30±1mm

Product

ModelInputOutputCurrentR&NEffiTempStorage temperature
LH-300-5II-F(S02)AC176-264V5V60A<300mV89%-40-70℃-40℃-85℃
  • 30mm ultra-thin power supply, wide range of applications
  • Wide input voltage range, strong adaptability
  • -30℃~+70℃ wide working temp.
  • According to US standard: UL60950
  • Using top brand components
  • Overvoltage, overcurrent, and overload protection
  • 100% full-load aging at high temperature , low failure rate and high reliability

SPECIFICATION (Measured at 230Vac, 25℃. Unless otherwise noted)

ItemSpecifications
Output Voltage Selectable5V;12V;24V
Overload protectionAutomatically resume work after the overload fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Output short circuit protectionAutomatically resume work after the output short-circuit fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Over voltage protectionPrevent from being damaged or burnt due to excessive voltage
Withstand voltageIP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc
Working temperature-40~70℃
Start-up Time<3Sec
Safety standardsGB4943/EN60950
EMCstandardsIEC61000-4
Connection9.5mm screw terminial
Dimension(L*W*H)215±1mm×115±1mm×30±1mm

Product

ModelInputOutputCurrentR&NEffiTempStorage temperature
PRA-350-5AC176-264V5V60A<200mV84%-40-70℃-40℃-85℃
PRA-350-12AC176-264V12V29A<600mV83%-40-70℃-40℃-85℃
PRA-350-24AC176-264V24V14.6A<600mV86%-40-70℃-40℃-85℃
  • 30mm ultra-thin power supply, wide applications
  • Wide input voltage range, strong adaptability
  • -30℃~+70℃ wide working temp.
  • According to US standard: UL60950
  • Using top brand components
  • Overvoltage, overcurrent, and overload protection
  • 100% full-load aging at high temperature , low failure rate and high reliability

SPECIFICATION (Measured at 230Vac, 25℃. Unless otherwise noted)

ItemSpecifications
Output Voltage Selectable12V;24V
Overload protectionAutomatically resume work after the overload fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Output short circuit protectionAutomatically resume work after the output short-circuit fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Over voltage protectionPrevent from being damaged or burnt due to excessive voltage
Withstand voltageIP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc
Working temperature-40~70℃
Start-up Time<3Sec
Safety standardsGB4943/EN60950
EMCstandardsIEC61000-4
Connection9.5mm screw terminial
Dimension(L*W*H)215±1mm×115±1mm×30±1mm

Product

ModelInputOutputCurrentR&NEffiTempStorage temperature
PRA-240-12AC176-264V12V20A<600mV83%-40-70℃-40℃-85℃
PRA-240-24AC176-264V24V10A<600mV87%-40-70℃-40℃-85℃
  • 30mm ultra-thin power supply, wide applications
  • Wide input voltage range, strong adaptability
  • -30℃~+70℃ wide working temp.
  • According to US standard: UL60950;
  • Using top brand components
  • Overvoltage, overcurrent, and overload protection
  • 100% full-load aging at high temperature , low failure rate and high reliability

SPECIFICATION (Measured at 230Vac, 25℃. Unless otherwise noted)

ItemSpecifications
Output Voltage Selectable12V;24V
Overload protectionAutomatically resume work after the overload fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Output short circuit protectionAutomatically resume work after the output short-circuit fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Over voltage protectionPrevent from being damaged or burnt due to excessive voltage
Withstand voltageIP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc
Working temperature-40~70℃
Start-up Time<3Sec
Safety standardsGB4943/EN60950
EMCstandardsIEC61000-4
Connection9.5mm screw terminial
Dimension(L*W*H)159±1mm×98±1mm×30±1mm

Product

ModelInputOutputCurrentR&NEffiTempStorage temperature
PRA-200-12AC176-264V12V16.7A<600mV83%-40-70℃-40℃-85℃
PRA-200-24AC176-264V24V8.3A<300mV87%-40-70℃-40℃-85℃
  • 30mm ultra-thin power supply, wide applications
  • Wide input voltage range, strong adaptability
  • -30℃~+70℃ wide working temp.
  • According to US standard: UL60950;
  • Using top brand components
  • Overvoltage, overcurrent, and overload protection
  • 100% full-load aging at high temperature , low failure rate and high reliability

SPECIFICATION (Measured at 230Vac, 25℃. Unless otherwise noted)

ItemSpecifications
Output Voltage Selectable12V;24V
Overload protectionAutomatically resume work after the overload fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Output short circuit protectionAutomatically resume work after the output short-circuit fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Over voltage protectionPrevent from being damaged or burnt due to excessive voltage
Withstand voltageIP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc
Working temperature-40~70℃
Start-up Time<3Sec
Safety standardsGB4943/EN60950
EMCstandardsIEC61000-4
Connection9.5mm screw terminial
Dimension(L*W*H)159±1mm×98±1mm×30±1mm

Product

ModelInputOutputCurrentR&NEffiTempStorage temperature
PRA-150-12AC176-246V12V12.5A<150mV86%-40-70℃-40℃-85℃
PRA-150-24AC176-246V24V6.5A<150mV88%-40-70℃-40℃-85℃
  • 30mm ultra-thin power supply, wide applications
  • Wide input voltage range, strong adaptability
  • -30℃~+70℃ wide working temp.
  • According to US standard: UL60950;
  • Using top brand components
  • Overvoltage, overcurrent, and overload protection
  • 100% full-load aging at high temperature , low failure rate and high reliability

SPECIFICATION (Measured at 230Vac, 25℃. Unless otherwise noted)

ItemSpecifications
Output Voltage Selectable12V;24V
Overload protectionAutomatically resume work after the overload fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Output short circuit protectionAutomatically resume work after the output short-circuit fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Over voltage protectionPrevent from being damaged or burnt due to excessive voltage
Withstand voltageIP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc
Working temperature-40~70℃
Start-up Time<3Sec
Safety standardsGB4943/EN60950
EMCstandardsIEC61000-4
Connection9.5mm screw terminial
Dimension(L*W*H)230±1mm×130±1mm×47±1mm

Product

ModelInputOutputCurrentR&NEffiTempStorage temperature
PRA-100-12AC176-264V12V8.5A<120mV86%-40-70℃-40℃-85℃
PRA-100-24AC176-264V24V4.2A<120mV88%-40-70℃-40℃-85℃

  • Constant voltage, IP67 protection
  • Rainproof, waterproof, can be used in humid and watery environments
  • Wide input voltage range, strong adaptability
  • Using top brand components, better quality
  • 100% full-load aging at high temperature , low failure rate and high reliability
  • Overvoltage, overcurrent, and overload protection

SPECIFICATION (Measured at 230Vac, 25℃. Unless otherwise noted)

ItemSpecifications
Output Voltage Selectable12V;24V;48V
Overload protectionAutomatically resume work after the overload fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Output short circuit protectionAutomatically resume work after the output short-circuit fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated
Over voltage protectionPrevent from being damaged or burnt due to excessive voltage
Withstand voltageIP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc
Working temperature-40~70℃
Start-up Time<3Sec
Safety standardsGB4943/EN60950
EMCstandardsIEC61000-4
Connection9.5mm screw terminial
Dimension(L*W*H)238±1mm×74±1mm×46±1mm

Product

FS-400-12ModelInputOutputCurrentR&NEffiTempStorage temperature
FS-400-12AC176-264V12V26.7A<300mV91%-40-70℃-40℃-85℃
FS-400-24AC176-264V24V15A<300mV93%-40-70℃-40℃-85℃
FS-400-48AC176-264V48V7.5A<300mV93%-40-70℃-40-70℃